Beam Diagnostics

We can supply a complete range of Laser Beam Profilers and Laser Beam Diagnostic systems for all types of laser. We also supply Shack-Hartmann wavefront measurement systems to instantaneously measure the phase and intensity of your laser.


Gentec Electro Optics

Gentec Electro-optics has an impressive 30-year track record of innovation and providing quality laser beam diagnostic equipment including CCD profiliers, knife-edge and scanning slit type probes. Gentec's diagnostic tools help you quantify, qualify and measure characteristics of your laser beam including laser beam profile, divergence and M2, etc.

  WinCamD-UCM BeamScope BeamR BeamMap
Laser Type Cw/Pulsed Cw/Pulsed Cw/Pulsed Cw/Pulsed
Min. Rep. Rate <1Hz to >50kHz 5kHz 100kHz 100kHz
Wavelength 350 - 1150nm (IR up to 1680nm) 189 - 1150nm; 800 - 1800nm; 1.5 - 4µm 190 - 1150nm; 800 - 1800nm; 1.5 - 4µm 191 - 1150nm; 800 - 1800nm; 1.5 - 4µm
Profiler Type CMOS Scanning slit, Scanning X-Y slit Scanning slit, knife edge mode Scanning slit or pinhole, knife edge mode
Imaging Size 8.6 x 6.9mm 25 x 45mm (with 2D stage) 5 x 6 mm / 4 x 4mm 5 x 6 mm / 4 x 4mm
Smallest Beam 70µm 5µm 0.5µm 0.5µm
Beam Dimensions 70µm - 8.6x6.9mm 5µm - 25mm 0.5µm - 5mm 0.5µm - 5mm
Pixel Size 6.7µm square - - -
Best Resolution 0.1µm/1um 0.1µm 0.1µm 0.1µm
2D / 3D 2D & 3D plots 2D (X-Y) 2D (X-Y) 3D (X-Y-Z)
M2 Yes (with lens) Yes (with 2D stage) No Yes
Application Diode measurements, beam wander and logging, optical assembly & industrial alignment, printer laser set-up Characterizing lasers, diodes in development, alignment, production test & QA Medical and diode laser assembly verification. Product development, assembly & QA Focusing telecom fibre assemblies, profiling printing, medical lasers. Product development, assembly & QA
Datasheet


NEW - Gentec WinCamD-UCM USB Laser Beam Profiling

Gentec-EO are proud to announce the launch of the new WinCamD-UCM. The WinCamD-UCM is an updated version of their extremely successful WinCamD, which now plugs directly into the USB port on your PC or laptop. An extremely compact, portable and easy to use instrument, WinCamD-UCM is the compact portable digital beam profiling camera you have been waiting for:

Gentec-EO WinCamD-UCM beam profiler
  • USB 2 direct connection with no external power supply required
  • CMOS sensor with 1.3 Megapixels, 6.7 x 6.7 µm pixels, 8.6(H) x 6.9(V) mm imaged area
  • Digital camera with 14-bit ADC, Image buffer RAM and in-head microprocessor
  • Window-free sensor as standard for no fringing
  • Pulsed laser auto-trigger and synchronization with synchronous (not rolling) shutter


Gentec BeamScope & BeamMap

Gentec's BeamScope & BeamMap are flexible laser diagnostic tools help you quantify, qualify and measure characteristics of your laser beam. Whether you want to measure the size, shape or energy distribution of your beam, or determine divergence and M2, we have the solution.

Gentec-EO WinCamD-UCM beam profiler
  • CCD type beam profilers measuring from UV to 10mm
  • M2, collimation, divergence measurement
  • 2D & 3D characterisation of energy distribution
  • Fibre optic adapters available
  • Full acquisition/analysis software included
  • Sub-micron X-Y beam profiling


Wavefront Sciences CLAS-2D Phase & Intensity Analysis

The CLAS-2D is a complete light analysis system (hence the name), which replaces intereferometers, beam profilers and beam quality meters. CLAS-2D simultaneously measures the phase and intesity of the transmitted light source, to provide wavefront aberration coefficients. The flexibility of the system ensures it can measure CW or pulsed beams at UV-VIS-IR wavelengths for laboratory, laser testing, optical testing, quality control, surface metrology and process monitoring applications.

Wavefront Sciences CLAS-2D Shack-Hartman sensor
  • CLAS-2D for UV-VIS sources (300nm to 1100nm)
  • CLAS-IR for IR sources (1.1um to 1.7um)
  • 30-120λ dynamic range
  • »λ/150 sensitivity
  • Measurement of CW or pulsed beams
  • Provides full Zernike reconstruction & coefficients
  • Extended & High Performance options available for increased resolution and sensitivity

For more information on Contact Lens & Optics Testing click here