Zygo ZMI Displacement Measurement Interferometers
|
ZMI - Displacement Measuring Interferometer Systems |
ZYGO is the technology and application support leader in heterodyne displacement interferometry. ZYGO offers complete solutions and support for your metrology application. An extensive line of standard products is only the beginning; ZYGO also provides:
- A World class engineering partnership
- Mechanical and optical design expertise
- Assembly and tooling support to help reduce your manufacturing costs, and improve your system accuracy
- Custom optical fabrication of stage mirrors, "L" mirrors and low mass, low thermal expansion monolithic structures
There are thousands of ZMI systems performing in the most demanding of applications. ZYGO's technology and products have been field proven over many years of use in leading edge products and standards laboratories worldwide.
Typical Applications
- Lithography tools: optical steppers and scanners, e-beam & laser mask writers
- Mask, wafer and LCD inspection and measurement tools, CD-SEM's
- Process equipment: memory repair tools, probers, die bonders, drilling tools
- Measurement and Calibration of high resolution or high frequency mechanical motions
- Single point diamond turning machine control
From the industry's highest resolution system, the ZMI 2000, to the new price and performance benchmark, the ZMI 501
ZMI 500 System Specifications
|
1-pass: 2.47nm - 2-pass: 1.24 nm Velocity: 1-pass: 950 mm/s - 2-pass: 475 mm/s Data Rate: up to 24 MHz Data Format: Parallel - Quadrature - Up/Down Pulse Axes per Board: 2 Electronics Format: Stand-Alone Enclosure Laser Source: Model 7705 |
ZMI 2000 System Specifications
|
1-pass: 0.62nm - 2-pass: 0.31 nm Velocity: 1-pass: 4.20 m/s - 2-pass: 2.10 m/s Data Age Uncertainty: ±1.2ns Data Rate: 10 MHz Data Format: Parallel - VME Axes per Board: 1 or 2 Electronics Format: 6U VME Laser Source: Model 7702 or 7712 |
ZMI 4000 System Specifications
|
1-pass: 0.31nm - 2-pass: 0.15 nm Velocity: 1-pass: 5.1 m/s - 2-pass: 2.55 m/s Data Age Uncertainty: ±0.2ns Data Rate: 10 MHz Data Format: Parallel - VME - High Speed Serial Axes per Board: 4 Electronics Format: 6U VME Laser Source: Model 7702 or 7712 |
ZMI-4000 electronics provide increased resolution and velocity (0.15nm at up to 2.55m/sec with 2-pass PMI).
Reliability
|
|
The Benefits of Heterodyne vs. Homodyne
|
Eliminates vibration induced false measurements Extremely robust for both OEM and end-user applications Easy to align and insensitive to signal amplitude changes High stability A single laser source can support multiple axes |
System Integration Simplified
|
Simplified P2 interfacing means single or multiple boards can be easily bussed to a single servo card or motor controller Fiber optic connections between the interferometers and the system electronics mean easier integration, lower costs, and better ESD isolation Reduced cost of ownership with less setup time and less maintenance time |