Pico Technology TA041 25MHz 700V Active Differential Probe
£319.00 £382.80
25 MHz 700 V differential oscilloscope probe 10:1/100:1. The TA041 is an active differential probe suitable for high common-mode voltage measurement applications up to ±700 V (DC + peak AC). It can be used with signal speeds of up to 25 MHz.
The Pico Technology TA041 is an active differential probe suitable for high common-mode voltage measurement applications up to ±700 V (DC + peak AC). It can be used with signal speeds of up to 25 MHz.
This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high-voltage differential measurements. Applications include making safe measurements in power circuit applications and acquisition of low-speed balanced differential signals found in serial communications buses.
TA041 differential oscilloscope probe specifications | |
---|---|
Bandwidth | DC to 25 MHz (–3 dB) |
Attenuation ranges | 10:1 / 100:1 |
DC accuracy | ±2% |
Rise time | 14 ns |
Input impedance | 4 MΩ ∥ 5.5 pF each side to ground |
Input voltage | |
Differential voltage range (10:1) Differential voltage range (100:1) |
±70 V (DC + peak AC) or 70 V RMS ±700 V (DC + peak AC) or 700 V RMS |
Common mode voltage range | ±700 V (DC + peak AC) or 700 V RMS (10:1 and 100:1) |
Absolute maximum voltage (differential or common-mode) |
±1400 V (DC + peak AC) or 1000 V RMS CAT III (10:1 and 100:1) |
Output | |
Swing | ±7 V into 2 kΩ load |
Offset (typical) | <±5 mV |
Noise (typical) | 0.7 mV RMS |
Source impedance (typical) | 1 Ω @ 1 kHz, 8 Ω @ 1 MHz |
CMRR (typical) | 86 dB @ 50 Hz; 66 dB @ 20 kHz |
Ambient operating temperature | −10 to +40 °C |
Ambient storage temperature | −30 to +70 °C |
Ambient operating humidity | 25 to 85% RH |
Power requirements | 4 AA cells or 6 V DC 60 mA mains adaptor or regulated 9 V DC 40 mA mains adaptor |
Length of input leads | 45 cm |
Length of BNC lead | 95 cm |
Weight | 400 g (inc. probes and PVC jacket) |
Dimensions | 170 mm x 63 mm x 21 mm |
PicoScope Software 6 Beginners Guide
An Introduction to PC Oscilloscopes
Choosing the right Pico Technology active differential probe
Write Your Own Review
Photo | Product | SKU | |
---|---|---|---|
Rigol RP1025D High Voltage Differential Probe, DC-50MHz, 1400Vpp | - | > | |
Rigol RP1100D High Voltage Differential Probe, 100MHz BW, 7000Vpp max | - | > | |
Pico Technology TA325 30/300/3000A AC 3-Phase Flex Current Probe, BNC Connector | - | > | |
AIM-TTi I-prober 520 Positional Current Probe, 5MHz, 20A | - | > | |
Rigol RP1002C Current Probe 100A Peak, 1 MHz Bandwidth | - | > | |
Rigol RP1001C Current Probe 100A Peak, 300 kHz Bandwidth | - | > | |
Pico Technology TA488 AD2201 200 MHz Active Differential Probe, BNC | - | > | |
Pico Technology TA489 AD2801 800 MHz Active Differential Probe, BNC | - | > | |
Pico Technology TA018 60 A AC/DC current probe, BNC | - | > |