Gas Sampling & Analysis Systems

Gas Sampling & Analysis Systems

Gas Sampling & Analysis Systems

From the novel BGA244 Binary Gas Analyser to sophisticated RGA based Universal Gas Analysers (UGA’s) we can on-line monitor and characterise gases from ultra high vacuum to high pressure both in the research lab and on a process plant.
⤑ Read More

Hide Sidebar List Grid
Set Descending Direction

10 Items

  • SRS BGA244 Binary Gas Analyser

    £3,758.00 £4,509.60

    New Binary Gas Analyser with 0.1% accuracy, using a novel acoustic technique for best accuracy and stability in industrial and scientific processes

    • Measures gas ratio of two gases, or purity of a single gas
    • Non-invasive measurements
    • <0.1 % composition error
    • Touch screen display
    • 4 samples per second measurement rate
    • USB, RS-232 and RS-422
  • SRS UGA100* Universal Gas Analyser

    • Operates from atmospheric pressure to UHV
    • 100, 200 and 300 amu systems
    • Fast response time (<0.2 s="" li="">
    • Electron multiplier standard on all systems
    • Stand-alone leak detection
    • Built-in heaters for bakeout to 120 °C
    • Windows software (uses RS-232 or Ethernet)
    • Operates in highly corrosive environments
    • Turbo pump venting (opt.)
    • Multi-capillary inlet (opt.)
  • SRS UGA200* Universal Gas Analyser

    • Operates from atmospheric pressure to UHV
    • 100, 200 and 300 amu systems
    • Fast response time (<0.2 s="" li="">
    • Electron multiplier standard on all systems
    • Stand-alone leak detection
    • Built-in heaters for bakeout to 120 °C
    • Windows software (uses RS-232 or Ethernet)
    • Operates in highly corrosive environments
    • Turbo pump venting (opt.)
    • Multi-capillary inlet (opt.)
  • SRS UGA300* Universal Gas Analyser

    • Operates from atmospheric pressure to UHV
    • 100, 200 and 300 amu systems
    • Fast response time (<0.2 s="" li="">
    • Electron multiplier standard on all systems
    • Stand-alone leak detection
    • Built-in heaters for bakeout to 120 °C
    • Windows software (uses RS-232 or Ethernet)
    • Operates in highly corrosive environments
    • Turbo pump venting (opt.)
    • Multi-capillary inlet (opt.)
  • SRS QMS100* High Pressure Sampling Systems

    • 100, 200 or 300 amu systems
    • Pressures from 10 mbar to 1 bar
    • Better than 1 amu resolution
    • <0.5 second response time
    • Compact, transportable design
    • 6 decades of dynamic range
    • RGA Windows software
    • RS-232 computer interface
  • SRS QMS200* High Pressure Sampling Systems

    • 100, 200 or 300 amu systems
    • Pressures from 10 mbar to 1 bar
    • Better than 1 amu resolution
    • <0.5 second response time
    • Compact, transportable design
    • 6 decades of dynamic range
    • RGA Windows software
    • RS-232 computer interface
  • SRS QMS300* High Pressure Sampling Systems

    • 100, 200 or 300 amu systems
    • Pressures from 10 mbar to 1 bar
    • Better than 1 amu resolution
    • <0.5 second response time
    • Compact, transportable design
    • 6 decades of dynamic range
    • RGA Windows software
    • RS-232 computer interface
  • SRS PPR100* Vacuum Process Monitoring System

    • 0.01, 0.1, 1.0 or 10 Torr inlet pressure 
    • 3 × 10-5 Torr-L/s flow rate 
    • 2 second response time (0.1 Torr) 
    • 100, 200 or 300 amu systems 
    • Field-replaceable electron multiplier and filament 
    • 6 orders of magnitude dynamic range 
    • RGA Windows software
  • SRS PPR200* Vacuum Process Monitoring System

    • 0.01, 0.1, 1.0 or 10 Torr inlet pressure
    • 3 × 10-5 Torr-L/s flow rate
    • 2 second response time (0.1 Torr)
    • 100, 200 or 300 amu systems
    • Field-replaceable electron multiplier and filament
    • 6 orders of magnitude dynamic range
    • RGA Windows software
  • SRS PPR300* Vacuum Process Monitoring System

    • 0.01, 0.1, 1.0 or 10 Torr inlet pressure
    • 3 × 10-5 Torr-L/s flow rate
    • 2 second response time (0.1 Torr)
    • 100, 200 or 300 amu systems
    • Field-replaceable electron multiplier and filament
    • 6 orders of magnitude dynamic range
    • RGA Windows software
Hide Sidebar List Grid
Set Descending Direction

10 Items