Fischione Model 2550 Cryo Transfer Tomography Holder
- Suits both tomography and single particle cryo-EM
- Works for other soft materials that may require cooling when imaging
- User friendly for specimen loading
- Unique mechanism for specimen unloading
- Extended field of view at high tilt up to 80° (in TEMs with cryo pole pieces)
- Resolution to 0.18 nm
- Low drift rate of 1.5 nm/minute
- Operating temperature below -175 °C
Simple specimen loading and transfer
The innovative design of the specimen tip makes loading and unloading of the specimen easy. To load a specimen, the holder is inserted into the cryo work station or the TEM to cool down. The holder dewar and the cryo work station are both filled with liquid nitrogen. The modular design of the cryo work station’s grid box allows you to reposition the reservoirs to enhance ease-of-use for both right- and left-handed operation.
Once a temperature of lower than -175 °C is achieved, a specimen is loaded from the grid box into the holder tip. The holder accepts a 3 mm diameter TEM specimen grid, which is secured by the holder’s one-piece, integrated cradle clamp. The clamp automatically closes when the holder tip is retracted. Optionally, the cradle clamp can be closed with forceps or with the supplied specimen tool. The thin profile of the clamp maximises specimen visibility, even at high-tilt angles.
The specimen holder tip retracts inside an actively cooled cryo shield located within the holder. This shield prevents any atmospheric water from condensing on the specimen during transfer to or from the microscope.
Rapid cool down, extended hold time
The Fischione Model 2550 Cryo Transfer Tomography Holder rapidly reaches a working temperature of less than -175 °C in either the cryo work station or a TEM. Hold times in excess of 4 hours are readily obtained with the 200 ml dewar capacity.
The temperature controller connects directly to the specimen holder dewar and displays the holder tip temperature.
Model 2550 Cryo Transfer Tomography Holder specifications | ||
Holder type
|
A single-tilt holder for cryo transfer and tomography of thin-film frozen-hydrated/vitrified specimens |
|
For transmission electron microscopes (TEMs) with a wider gap pole piece (an approximate 5 mm gap for tomographic studies) |
||
Standard specimen cup/ holder tip material |
Beryllium copper |
|
Cryogen |
Liquid nitrogen |
|
Specimen grid size |
3 mm diameter |
|
Field of view |
2 mm diameter at 0° tilt |
|
Resolution |
0.18 nm at 0° tilt |
|
Drift |
1.5 nm/min-1 |
|
Maximum tilt range |
Up to ± 80° |
|
Dewar capacity |
200 ml |
|
Maximum operating temperature |
Up to 110 °C |
|
Maximum bake-out temperature |
Up to 110 °C |
|
Minimum operating temperature |
< -175 °C |
|
Time to reach minimum operating temperature |
< 30 minutes (in microscope) |
|
Hold time at minimum operating temperature |
> 4 hours |
|
Warranty |
One year |
|
All specifications depend on the microscope model, pole-piece type, and aperture position. For ultimate resolution and drift performance, the TEM must meet the manufacturer’s specifications. |