Home Current and Voltage Sources Source Measure Units SMU Source Measure Units SMU SRS DC215 — Precision DC Voltage/Current Source

SRS DC215 — Precision DC Voltage/Current Source

Availability: In stock


Product Code:
76578
Manufacturer: Stanford Research Systems
Special Price £4,038.11 £4,845.73 Regular Price £4,163.00 £4,995.60
  • Low-noise, precision DC source
  • Sources voltage up to ±32 V
  • Sources current up to ±240 mA
  • 4 quadrant operation
    (voltage/current source/sink)
  • 5½-digit output resolution
  • Output sequences (up to 1k steps)
  • Data logging and USB mass storage
  • Multi-unit synchronization
  • GPIB, ethernet & RS-232 interfaces

More info and finance questions

Lambda Exclusive Promotion:
Additional 12 months warranty for free (2 years total) via our UK Service Centre.

The SRS DC215 DC Voltage/Current Source lets you generate extremely low-noise voltage and current signals with the precision and accuracy needed in the toughest applications. The instrument also measures and displays voltage and current, making it a convenient signal monitor in addition to being a precision source.

The DC215's bipolar, four-quadrant output lets you source and sink voltage (±32 V) and current (±240 mA). In four-wire mode, the instrument corrects for lead resistance delivering accurate voltage and current to your load.

Up to 1000 step sequences can be output, which are controlled by internal or external triggers. Voltage and current measurements can be logged to the USB port or one of the computer interfaces.

Low-Noise Design
In addition to its precise 5½ digit resolution, the DC215 is highly stable and accurate. It also has impressive noise performance: less than 75 µVpp (10 V range) and 70 nApp (10 mA range).

And with its custom linear power supplies, there is no need to worry about switching frequency interference — there isn't any.

Biploar, Four-Quadrant Output
The DC215 can source or sink voltage or current and is fully floating. Two-wire or four-wire operation can be selected. In four-wire mode (remote sense), the instrument senses the output voltage at the load eliminating the effect of lead resistance. Programmable voltage and current limits can protect sensitive loads.

Voltage and Current Monitoring
Unlike some competitive models, voltage and current measurement & display is a standard feature of the DC215. A common use of this feature is to monitor current while generating voltage, or monitor voltage while generating current. These measured values can be logged to the USB port or to a computer.

Sequencing and Data Logging
The DC215 lets you define up to 1000 step output sequences, with full control of the output range and value of each step. Sequences can be created on the DC215 directly, or downloaded from a USB drive or over one of the computer interfaces. Internal and external step triggers and ramping control the output sequence.

Multi-Unit Synchronization
When channel expansion is needed, the DC215 has built-in digital I/O for synchronizing multiple units. It also supports synchronization to external DMMs or other devices.

Computer Interfaces
The DC215 is fully programmable over its RS-232, GPIB and Ethernet interfaces. All functions of the instrument can be set or read via the interfaces.

Voltage Monitor

Range

Source Range

Max Resolution*

Stability (24 hr.)

±(ppm of setting + µV)

Accuracy (1 yr.)

±(ppm of setting + µV)

Temp. Coef.

±(ppm of setting + µV)

Current Out

(all ranges)

±32.000 V

10 µV

50 + 100

tbd

tbd

Voltage Out

10 mV

±12.0000 mV

10 nV

20 + 2

tbd

tbd

100 mV

±120.000 mV

100 nV

20 + 3

tbd

tbd

1 V

±1.20000 V

1 µV

10 + 5

tbd

tbd

10 V

±12.0000 V

1 µV

10 + 10

tbd

tbd

32 V

±32.000 V

10 µV

10 + 30

tbd

tbd

 

Current Monitor

 

Range

Source Range

Max Resolution*

Stability (24 hr.)

±(ppm of setting + µV)

Accuracy (1 yr.)

±(ppm of setting + µV)

Temp. Coef.

±(ppm of setting + µV)

Voltage Out

(all ranges)

±240.00 mA

100 nA

50 + 3000

tbd

tbd

Current Out 1 mA

 

±1.20000 mA

 

10 nA

 

10 + 10

 

tbd

 

tbd

10 mA

±12.0000 mA

10 nA

10 + 1000

tbd

tbd

100 mA

±120.000 mA

100 nA

20 + 800

tbd

tbd

200 mA

±240.00 mA

100 nA

20 + 1400

tbd

tbd

* Maximum resolution is always available over remote interfaces but may be limited on the front panel

 

V & I Monitor

Integration time Slow (588 ms), Medium (294 ms), Fast (147 ms), Very Fast (74 ms) Noise rejection 87 dB at 50/60 Hz
Triggering                Auto, Timed (0.1 to 3600 s), Ready, Command
Limiting
Limit type Positive and negative limits
I-limit ranges  1, 10 and 30 V ranges 
I-limit magnitude       1 mA to 240 mA
I-limit resolution             1 mA
V-limit ranges  1, 10, 100 and 200 mA ranges 
V-limit magnitude         0.1 V to 32 V
V-limit resolution            0.1 V
Response Time (typ.)
HiBW mode <8 ms
LoBW mode <10 ms
Accuracy 0.1 % of final value (typ.)
Reactive Load
Capacitive load  ≥100 µF (LoBW) (Voltage Out and Voltage Limit) 
Reactive load  ≥1 mH (LoBW) (Current Out and Current Limit)
Logging
Storage                             Log data to a USB thumb drive or over the remote interfaces
Number of points             1 through 199999, or continuous
Output Sequences  
Number of steps              2 to 1000
Trigger source                  Manual, Timed (0.1 to 3600 s), Command, External Step Trigger
General
Interfaces                          IEEE488.2, RS-232, and Ethernet
Operating Temp.    0 to 50 °C, ≤85 % RH, non-condensing
Power          40 W, 100/120/220/240 VAC, 50/60 Hz
Dimensions                      8.3” × 3.55” × 16”  (WHL)
Weight                              10 lbs.

All performance specifications after 1 hour warmup at 23 ±1 °C, unless otherwise stated.

Write Your Own Review
You're reviewing:SRS DC215 — Precision DC Voltage/Current Source
Your Rating
PhotoProduct Price
SRS CS580 Voltage Controlled Current Source, ±50 V, 100fA to 100mASRS CS580 Voltage Controlled Current Source, ±50 V, 100fA to 100mA 4,811.00
SRS DC205 Precision DC Voltage SourceSRS DC205 Precision DC Voltage Source 3,205.00