Home Current & High Voltage Probes Rigol RP1100D High Voltage Differential Probe, 100MHz BW, 7000Vpp max

Rigol RP1100D High Voltage Differential Probe, 100MHz BW, 7000Vpp max

Availability: In stock


Product Code:
38478
Manufacturer: Rigol
£662.00 £794.40

Differential probes are used to make differential measurements between the positive terminal to the negative terminal and are not referenced to ground. This improves the CMRR, probing loading around 50% of standard single ended probes.

  • Bandwidth: 100MHz
  • Maximum Voltage: 7000Vpp

Compatible with all Rigol oscilloscopes.

More info and finance questions

Rigol RP1100D high voltage differential probe, 100MHz BW, 7000Vpp max.

Model

RP1100D

Maximum Differential Input Voltage

7.0kV

Attenuation Ratios x100, x200, x500, x1000
Bandwidth DC to 100MHz (x200, x500, x1000) 
DC to 50MHz (x100)
Power Supply Requirements 9.0V, 0.4W
Input Impedance
Differential: 100MΩ/1.2pF, Single-ended and to ground: 50MΩ/2.3pF
Output Voltage ≤ ±7.0V
Output Impedance 50Ω
Rise Time X200, X500 or X1000 attenuation ratio: 7ns X100 attenuation ratio: 14ns
Common-mode Rejection 60Hz: > 80dB, 100Hz: > 60dB1MHz: > 50dB
Power Supply  Specified external 9V DC power supply (must be specified products acknowledged by our company)
Power Consumption  0.4 watt

Weight

280g. 
Write Your Own Review
You're reviewing:Rigol RP1100D High Voltage Differential Probe, 100MHz BW, 7000Vpp max
Your Rating
PhotoProduct SKU
Pico Technology TA041 25MHz 700V Active Differential ProbePico Technology TA041 25MHz 700V Active Differential Probe- >
Rigol RP1025D High Voltage Differential Probe, DC-50MHz, 1400VppRigol RP1025D High Voltage Differential Probe, DC-50MHz, 1400Vpp- >
Pico Technology TA325 30/300/3000A AC 3-Phase Flex Current Probe, BNC ConnectorPico Technology TA325 30/300/3000A AC 3-Phase Flex Current Probe, BNC Connector- >
AIM-TTi I-prober 520 Positional Current Probe, 5MHz, 20A AIM-TTi I-prober 520 Positional Current Probe, 5MHz, 20A - >
Rigol RP1002C Current Probe 100A Peak, 1 MHz BandwidthRigol RP1002C Current Probe 100A Peak, 1 MHz Bandwidth- >
Rigol RP1001C Current Probe 100A Peak, 300 kHz BandwidthRigol RP1001C Current Probe 100A Peak, 300 kHz Bandwidth- >
Pico Technology TA488 AD2201 200 MHz Active Differential Probe, BNCPico Technology TA488 AD2201 200 MHz Active Differential Probe, BNC- >
Pico Technology TA489 AD2801 800 MHz Active Differential Probe, BNCPico Technology TA489 AD2801 800 MHz Active Differential Probe, BNC- >
Pico Technology TA018 60 A AC/DC current probe, BNC Pico Technology TA018 60 A AC/DC current probe, BNC - >