EverBeing Low Leakage Triaxial Cable (1.0 m) Triax
1.0m low noise Triax cable terminated at both ends with 3-slot triax male plug. Used to connect from the shielded box to the Source Measure Unit (SMU).
1.0m low noise Triax cable made from premium TRC-50-1 Triax cable and terminated at both ends with 3-slot triax male plug. Used to connect from the shielded box to the Source Measure Unit (SMU). Suitable alternative for the 16494A and 4200-TRX triaxial cables.
The Everbeing low noise Triax cables made are made from premium TRC-50-1 Triax cable and terminated at both ends with 3-slot triax male plug. These can be used for new installations or suitable replacements for 16494A and 4200-TRX triaxial cables.
EC-515 Triaxial Extension Cable. Triaxial Male Connector, 1.0 metre Triaxial Cable Length, Triaxial Male Connector. Peak voltage 1.8 kV VDC with a 50 Ohm Impedance. Part Number 60067
EC-5155 Triaxial Extension Cable. Triaxial Male Connector, 1.5 metre Triaxial Cable Length, Triaxial Male Connector. Peak voltage 1.8 kV VDC with a 50 Ohm Impedance. Part Number 73564
EC-525 Triaxial Extension Cable. Triaxial Male Connector, 2.0 metre Triaxial Cable Length, Triaxial Male Connector. Peak voltage 1.8 kV VDC with a 50 Ohm Impedance. Part Number 60066
Triax Cable Specs:
Cable Designation |
TRC-50-1 |
TRC-50-2 |
TRC-75-1 |
TRC-75-2 |
Impedance (Ohms) |
50±2 |
50±2 |
75±5 |
75±5 |
Nominal outer dia. |
0.156 |
0.245 |
0.189 |
0.245 |
Outer braid dia. |
0.121 |
0.210 Max |
0.150 |
0.205 |
Core outer dia. |
|
|
|
|
Dielectric outer dia. |
0.047 |
0.116 |
0.073 |
0.116 |
Inner braid outer dia. |
0.069 Max |
0.146 Max |
0.093 |
0.146 Max |
Inner jacket outer dia. |
0.101 |
0.175 |
0.130 |
0.175 |
Conductor outer dia. |
0.0150 |
0.0370 |
0.0120 |
.0185 |
Operating temperature Range |
-40°C to +75°C |
-40°C to +80°C |
-40°C to +80°C |
-40°C to +80°C |
Minimum bend radius (in.) |
0.75 |
1.25 |
1.00 |
1.25 |
Max. Opr. VDC |
2.0 KV |
6.0 KV |
2.0 KV |
6.0 KV Max |
Max. Opr. VAC (RMS) |
1.0 KV |
2.0 KV |
1.0 KV |
2.0 KV Max |
Capacitance pf/ft. (Max) |
29.50 |
32.00 (1) |
20.00 |
20.50 (1) |
Cond. loop res. (Ohms/M ft.) |
|
|
|
|
Atten. dB/100 ft.: |
|
|
|
|
1 MHz |
2.800 |
0.500 |
0.900 |
0.480 |
3 MHz |
3.100 |
0.800 |
1.300 |
0.880 |
4 MHz |
3.300 |
0.900 |
1.500 |
1.010 |
5 MHz |
3.400 |
1.100 |
1.700 |
1.100 |
7 MHz |
3.700 |
1.300 |
1.900 |
1.300 |
10 MHz |
4.100 |
1.500 |
2.400 |
1.500 |
20 MHz |
5.50 |
2.30 |
3.60 |
2.30 |
30 MHz |
7.00 |
2.90 |
4.50 |
2.90 |
40 MHz |
7.50 |
3.40 |
5.40 |
3.30 |
50 MHz |
9.10 |
3.90 |
6.10 |
3.60 |
100 MHz |
14.00 |
5.80 |
9.70 |
5.20 |
200 MHz |
22.00 |
8.80 |
16.50 |
7.60 |
500 MHz |
40.00 |
15.30 |
28.50 |
10.80 |
700 MHz |
50.00 |
18.00 |
36.00 |
14.70 |
1 GHz |
63.00 |
23.00 |
45.00 |
17.60 |
Shielded coverage |
93% Min. |
93% |
93% Min. |
93% |
Twist per ft. |
|
|
|
|