Typical test applications:
- Optical power at 8 calibrated λ, -60 to +10 dBm range.
- Loss on MM fibre 850 / 1300 nm, 40 dB range, EF compliant.
- Optical loss on SM fibre at 1300 nm, 28 dB range.
- Reporting software for cable loss (manual data entry).
- Optical continuity / tone source & meter with 12 Multi-Fiber ID fibre, 40 dB range.
- Generally meets safety regulations & standards based test procedures.
Connector & battery summary:
- SC interchangeable connector adapters.
- Meter accepts PC & APC polish. Source accepts PC polish.
- Meter 2 x AAA alkaline. Run time >300 hours.
- Source 2 x AAA alkaline. Run time >35 hours.
Includes:
- Fibre optic laser test source T9812A
- Pocket fibre optic power meater T9600A
- Canvas carrying pouch
Attribute Name | Attribute Value |
---|---|
Detector type | InGaAs |
Response wavelength | 600 ~ 1700 nm |
Calibration wavelengths | 850, 1300, 1310, 1390, 1490, 1550, 1577, 1610, 1625 nm |
Power range | +5 ~ -60 dBm |
Mid-range linearity | 0.04 dB (typical) |
Total uncertainty | 0.3 dB (max) |
Wavelength sensitivity (± 30 nm) | 0.03 dB (typical) |
ID tone detection sensitivity | up -50 dBm |