Home Optical Loss & Test Set Kits Tempo T23422OLV Ultra-Stable 2W Loss Length ORL Tester

Tempo T23422OLV Ultra-Stable 2W Loss Length ORL Tester

Availability: In stock


Product Code:
76925
Manufacturer: Tempo
£4,763.00 £5,715.60

A Two-Way Optical Loss Test set (OLTS) that’s perfect for medium to ultra high fibre count loss, length and optical return loss testing applications on single mode fibre at 1310/1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL Visitester feature mixes a VFL in with the test signal during Autotest. In addition to operating as a typical VFL, it gives positive visual identification of a fiber to be connected for loss testing.

 

More info and finance questions

Each SM fibre needs just one test hook-up and one key press for a complete 2W/bidirectional loss, length & ORL test, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

A pair of instruments both display length bi-directional loss, & ORL fibre testing each end, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone ultra-stable light source & power meter, VFL, ORL meter, or tone generator/detector.

ORL sensitivity on this model is typically adequate for installed cable testing, but is limited by the PC connector. For best ORL sensitivity, select a model with an APC connector.

  • 25% of the size / weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length & ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass / Fail display
  • 8,000 fiber memory and USB key file dump
  • KITS™ reporting software (download)
  • Autotest optical power meter, >25 λ, 1 % accuracy
  • Traceable reports: source stability & λ, meter cal & linearity, ORL cal
  • 80 hr alkaline battery life
  • 3 Year warranty and calibration cycle
Attribute Name Attribute Value
Modulated output (source) 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones
Output wavelength (source) 1310-1550 nm Laser, VisiTester
Output power (source) -7 dBm ±1 dB @ SMF
Adjust output power (source) Adjustable over 7 dB in 0.01 dB steps
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) 0.03 dB
Stability over temperature (source) 0.2 dB (max)
Wavelength drift (source) 0.4 nm per °C (typical)
Wavelength initial tolerance @ 25 °C (source) 20 nm
Spectrum width @ FWHM (source) 3 nm (typical)
Reconnection repeatability @ 95% confidence (source) 0.1 dB
Length range (2-way Autotest only) 27 dB
Length accuracy (2-way Autotest only) 0.01% ± 4 meters
Length resolutions 1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)
Loss range (2-way Autotest) 44 dB
Loss repeatability & loss linearity (2-way Autotest) 0.04 dB
Loss range (1-way Autotest) 44 dB
Loss repeatability & loss linearity (1-way Autotest) 0.04 dB
ORL range 0 ~ >60 dB
ORL port isolation > 60 dB
ORL accuracy 0.2 dB
ORL resolution 0.01 dB (@ 0 ~ 50 dB), 0.1 dB (@ 50 ~ 65 dB)
VisiTester wavelength 650 ± 5 nm
VisiTester power 0 dBm ± 1 dB @ SMF
VisiTester laser safety Class 1, IEC60825-2
VisiTester blink rate (manual) CW or 2 Hz
   
Detector type (meter) InGaAs
Response wavelength (meter) 600 ~ 1700 nm
Calibration wavelengths (meter) 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy (meter) 1 % (0.06 dB)
Mid-range linearity (meter) 0.04 dB (typical)
Power range (meter) +10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)
Total uncertainty (meter) 0.3 dB (max)
Resolution (meter) 0.01 dB
Polarization sensitivity (meter) < 0.05 dB (typical)
ID tone detection & Autotest sensitivity (meter) Up to -50 dBm
Autotest: 1-way: compatible with other T23400 & T27400 models / 2-way: compatible with identical model only
Tone detection (meter) 150 ~ 9999 Hz ± 1 %
USB interfaces USB-micro for power & software / USB-A for memory key
Software KITS (free download)
Power Battery / External power via USB
Battery life Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)
Battery type 2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via USB)
Auto off Selectable
Display 74 mm x 55 mm high contrast LCD
Case Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested
Memory For 8,000 fibers / Unlimited on USB
Size 190 mm x 105 mm x 35 mm
Unit weight 0.42 kg
Shipping weight 1.5 Kg
Operating / storage temperature -15 to 55 °C / -25 to 70 °C
Relative humidity 0 ~ 95 %
Warranty 3 years
Calibration validity (ISO/IEC 17025) 3 years
Write Your Own Review
You're reviewing:Tempo T23422OLV Ultra-Stable 2W Loss Length ORL Tester
Your Rating
PhotoProduct Price
Tempo TK056 Simple Test Kit SM Tempo TK056 Simple Test Kit SM 1,495.00
Tempo TK052 Simple LAN Test Kit MMTempo TK052 Simple LAN Test Kit MM 1,526.00
Tempo TK038 Simple Test Kit SM MMTempo TK038 Simple Test Kit SM MM 2,500.00
Tempo TK077 Advanced Test Kit SM Tempo TK077 Advanced Test Kit SM 2,604.00
Tempo TK076 Advanced Test Kit SM MMTempo TK076 Advanced Test Kit SM MM 3,250.00
Tempo T27622 Dual Optical Loss Test Set + VisiTesterTempo T27622 Dual Optical Loss Test Set + VisiTester 2,267.00
Tempo T27603 MM Optical Loss Test Set + VisiTesterTempo T27603 MM Optical Loss Test Set + VisiTester 2,381.00
Tempo T27624 Quad Optical Loss Test Set + VisiTesterTempo T27624 Quad Optical Loss Test Set + VisiTester 2,799.00
Tempo T27403LV Multimode Two-Way Loss & Length Test SetTempo T27403LV Multimode Two-Way Loss & Length Test Set 3,573.00
Tempo T27422LV Single-Mode Two-Way Loss & Length Test SetTempo T27422LV Single-Mode Two-Way Loss & Length Test Set 4,526.00
Tempo T27424LV-APC Quad MM & SM Two-Way Loss & Length Test SetTempo T27424LV-APC Quad MM & SM Two-Way Loss & Length Test Set 5,730.00
Tempo T23403OLV-APC-50U Ultra-Stable 2W Loss, Length & ORL TesterTempo T23403OLV-APC-50U Ultra-Stable 2W Loss, Length & ORL Tester 3,811.00
Tempo T23424OL-APC Ultra-Stable Two-Way Loss, Length & ORL TesterTempo T23424OL-APC Ultra-Stable Two-Way Loss, Length & ORL Tester 6,430.00