Tempo T27424LV-APC Quad MM & SM Two-Way Loss & Length Test Set
A Quad Two-Way Optical Loss Test set (OLTS) that’s perfect for medium to ultra high fibre count loss & length testing applications on both multimode fibre with a PC connector, and single mode fibre with an APC connector, at 850/1330nm & 1310/1550 nm. A pair of these compact SM & MM instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL VisiTester on the SM port mixes a VFL in with the test signal during SM Autotest. It operates as a stand-alone VFL, or gives positive visual identification of a fiber to be connected during MM loss testing.
Each fibre needs just one test hook-up and one key press for a complete bidirectional insertion loss and length test, and the same test method is used for both multimode and single mode fibre, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.
A pair of instruments both display bi-directional loss and length, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone light source & power meter, VFL or tone generator/detector.
- 25% of the size / weight, 7x the battery life of competitors
- Bidirectional Autotest loss & length testing on one fiber
- Real time Pass / Fail display
- 8,000 fiber memory and USB Flash Drive file dump
- KITS™ reporting software
- Autotest optical power meter, >25 λ, 1 % accuracy
- Traceable calibration reports: power meter & linearity, source λ & stability
- 80 hr alkaline battery life
- 3 Year warranty and calibration cycle
- EF compliant multimode sources
Attribute Name | Attribute Value |
---|---|
Modulated output (source) | 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones |
Output wavelength (source) | Port 1: 1310, 1550 nm Laser APC / Port 3: 850, 1300 nm LED |
Output power (source) | -7 dBm ±1 dB (@ 9/125 µm for 1310, 1550 m) / -27 dBm ±1 dB (@ 62.5/125 µm for 850, 1300 nm) |
Adjust output power (source) | Adjustable over 7 dB in 0.01 dB steps (for 1310, 1550 nm) / Fixed (for 850, 1300 nm) |
Wavelength initial tolerance @ 25 °C (source) | 20 nm (for 1310, 1550 nm) |
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) | 0.04 dB (for 1310, 1550 nm) / 0.01 dB (for 850, 1300 nm) |
Stability over temperature (source) | 0.6 dB (max for 1310, 1550 nm) / 0.35 dB (max for 850, 1300 nm) |
Spectrum width @ FWHM (source) | 3 nm (typical for 1310, 1550 nm) |
Wavelength drift (source) | 0.4 nm per °C (typical for 1310, 1550 nm) / 0.4 nm per °C (typical for 850, 1300 nm) |
Mode controlled (source) | 850, 1300 nm (50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178) |
Reconnection repeatability @ 95% confidence (source) | 0.1 dB (for 1310, 1550 nm Laser) / 0.05 dB (for 850, 1300 nm LED) |
Length range (2-way Autotest only) | 27 dB (for 1310, 1550 nm) / 4.5 dB @ 62.5um (for 850, 1300 nm) |
Length accuracy (2-way Autotest only) | 0.01% ± 4 meters |
Length resolutions | 1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km) |
Loss range (2-way Autotest) | 44 dB (for 1310, 1550 nm) / 24 dB @ 62.5 µm (for 850, 1300 nm) |
Loss repeatability & loss linearity (2-way Autotest) | 0.04 dB (for 1310, 1550 nm) / 0.06 dB (for 850, 1300 nm) |
Loss range (1-way Autotest) | 44 dB (for 1310, 1550 nm) / 24 dB @ 62.5 µm (for 850, 1300 nm) |
Loss repeatability & loss linearity (1-way Autotest) | 0.04 dB (for 1310, 1550 nm) / 0.06 dB (for 850, 1300 nm) |
VisiTester wavelength | 650 ± 5 nm |
VisiTester power | 0 dBm ± 1 dB @ SMF |
VisiTester laser safety | Class 1, IEC60825-2 |
VisiTester blink rate (manual) | CW or 2 Hz |
Detector type (meter) | InGaAs |
Response wavelength (meter) | 600 ~ 1700 nm |
Calibration wavelengths (meter) | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
Power range (meter) | +10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm) |
Accuracy (meter) | 1 % (0.06 dB) |
Mid-range linearity (meter) | 0.04 dB (typical) |
Total uncertainty (meter) | 0.3 dB (max) |
ID tone detection & Autotest sensitivity (meter) | Up to -50 dBm |
Resolution (meter) | 0.01 dB |
Polarization sensitivity (meter) | < 0.05 dB (typical) |
Tone detection (meter) | 150 ~ 9999 Hz ± 1 % |
Autotest | 1-way: compatible with other T23400 & T27400 models / 2-way: compatible with identical model only |
USB interfaces | USB-micro for power & software / USB-A Flash Drive |
Software | KITS (free download) |
Power | Battery / External power via micro-USB |
Battery life | Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical) |
Battery type | 2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via micro-USB) |
Auto off | Selectable |
Display | 74 mm x 55 mm high contrast LCD |
Case | Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested |
Memory | For 8,000 fibers / Unlimited on USB Flash Drive |
Size | 190 mm x 105 mm x 35 mm |
Unit weight | 0.42 kg |
Shipping weight | 1.5 Kg |
Operating / storage temperature | -15 to 55 °C / -25 to 70 °C |
Relative humidity | 0 ~ 95 % |
Warranty | 3 years |
Calibration validity (ISO/IEC 17025) | 3 years |
Tempo T23400/T 27400 Series Handhelad 2-way + Length + ORL Fibre Certifier Datasheet
Tempo Optical Power Meters & Light Sources Datasheet
Tempo Optical Power Meter Calibration Glossary
Tempo Insertion Loss Datasheet