Typical test applications:
- Optical power at 25 calibrated λ, -70 to +10 dBm range.
- Optical loss on SM fiber 1310 / 1550 nm, 70 dB range.
- Loss testing automation & reporting with AutoTest and KITS™ software.
- Optical continuity / tone, 12 fiber Multi-Fiber ID, 50 dB range.
- Generally meets safety regulations & standards based test procedures.
Connector & battery summary:
- SC interchangeable connector adapters.
- Meter accepts PC & APC polish. Source accepts PC polish.
- Meter 2 x AA alkaline. Run time >1000 hours. Micro USB pwr /charging.
- Source 2 x AA alkaline. Run time >80 hours. Micro USB pwr /charging.
Includes:
- Dual laser optical test source T2822
- Handheld optical power meter T2600
- Padded canvas carry pouch OPT149
Attribute Name | Attribute Value |
---|---|
Detector type | InGaAs |
Calibration accuracy | 1% (0.06 dB) |
Response wavelength | 600 ~ 1700 nm |
Calibration wavelengths | 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm |
Power range | +10 ~ -60 dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm) |
Mid-range linearity | 0.04 dB (typical) |
Total uncertainty | 0.3 dB (max) |
Wavelength sensitivity (± 30 nm) | 0.03 dB (typical) |
ID tone detection & Autotest sensitivity | Up to -50 dBm |
Tempo T2400/2800 Series Handheld Optical Light Source Datasheet
Tempo T2600 Series Hand Held Fiber Meter Datasheet
Tempo Optical Power Meters & Light Sources Datasheet
Tempo Optical Power Meter Calibration Glossary
Tempo Insertion Loss Datasheet
Write Your Own Review