AIM-TTi Low Distortion 1kW Power Source, AC1000A
- Provides an EN61000–3–2 compliant source
- 1000W power capability at 230V
- Up to 4·4A rms load current and up to 10A peak currents
- Comprehensive overload protection
- Connection via standard power connectors
The AC1000A is an innovative, low cost, pure power source designed specifically for use with a harmonics analyser such as the TTi HA1600A. It permitts compliance quality measurements to EN61000–3–2 in situations where the quality of the AC supply is poor or variable.
Optional low distortion 1kW power source
The AC1000A is a low cost pure power source designed specifically for use with a harmonics analyser such as the HA1600A. The AC supply available at a standard wall socket is usually distorted. This comes about because of nonlinear loads (non–resistive loads) on the AC supply such as transformers, fluorescent lights, switched–mode power supplies etc. The effect of this is to flatten off the top of the sine wave causing significant distortion.
In a typical factory environment this distortion is so significant that it is easily visible using an oscilloscope. EN61000–3–2 requires that the source supply provides a pure voltage waveform to the equipment under test. The harmonic currents can differ significantly when a pure source is used, so for true compliance measurements it is important that any testing is performed with a device such as the AC1000A.
Because of the large increase in the peak currents that can result from having a pure sinewave maims voltage supply, the AC1000A is also very useful for stress testing a wide variety of power supplies types within electronic equipment.
Compact and portable, the AC1000A is rated at 1000 V·A for 230 V operation at up to 35°C ambient. Maximum continuous rms current is 4.4A with a peak current capability of 10A.
Input Voltage: | 230V AC or 115V AC, 50 or 60Hz to order. Installation Category II. |
Supply Tolerances: | Voltage ± 10%. Frequency ± 1% |
Output Voltage: | Tracks the amplitude of the fundamental of the input voltage. A variable voltage input may be used to adjust the output voltage to within the limits specified by EN61000–3–2. Dependent on the purity of the input but will generally meet the requirements of EN61000–3–2. |
Output Distortion: | |
Output Current: | Maximum continuous output current is 4·4A (10A peak). |
Output Power: | Maximum output power is input voltage x 4·4 VA |
Input Connection: | IEC connector; front panel switch. |
Output Connection: | U.K., Schuko, or other national outlet sockets. Load power switch can be set to DIRECT or CORRECTED for ‘A–B’ comparisons. |
Protection: | Thermal trip automatically diverts load to a DIRECT connection in the event of thermal overload. |
Operating Range: | +5°C to +35°C at full rated output; 20% to 80% RH (non-condensing). |
Storage Range: | –40°C to +70°C |
Environmental: | Indoor use at altitudes to 2000m, Pollution Degree 2. |
Safety: | Complies with EN61010–1 |
EMC: | Complies with EN61326-1 |
Size: | 357 x 132 x 235mm mm (W x H x D) |
Weight: | 5.5 kg. |