GoGo Instruments ECH600S Electrical Heating and Cooling Stage
- Temperature range: -190°C~600°C
- Temperature stability: ±0.1°C
- Supports reflection/transmission modes
- Chamber can be upgraded to vacuum
- High-precision temperature control
- Professional temperature control software
- Customisation available
The GoGo Instruments ECH600S is a precision electrical heating and cooling stage designed for temperature-dependent electrical characterisation of advanced materials, semiconductor devices, thin films, and electronic components. Combining liquid nitrogen cooling with resistive heating technology, the platform delivers stable thermal control from −190 °C to +600 °C while supporting low-noise electrical measurements and in-situ optical observation.
Built on a compact optical-stage architecture, the ECH600S integrates precision electrical probing, programmable temperature control, and reflection/transmission optical compatibility within a lightweight, low-profile platform suitable for microscopy and spectroscopy integration.
Key Features
- Wide temperature range: −190 °C to +600 °C
- Temperature stability of ±0.1 °C
- Liquid nitrogen cooling with resistive heating
- Heating rates up to 150 °C/min
- Cooling rates up to 40 °C/min
- Reflection and transmission optical modes
- Four magnetic probe holders with gold-plated probes
- Screw-top chamber design for rapid sample access
- Optional vacuum chamber upgrade
- Professional programmable temperature control software
- LabVIEW and C# SDK support for automation
- Compact low-profile stage for microscope integration
- Custom configurations available
Optical Access and Stage Design
The ECH600 supports both reflected-light and transmitted-light experimental configurations, enabling combined electrical and optical analysis. The compact low-profile design enables integration with optical microscopes, spectroscopy systems, and customised in-situ measurement platforms.
Vacuum-Compatible Configuration
The standard ECH600S operates under atmospheric conditions, with optional upgrade paths for vacuum chamber integration.
Compact Microscope-Compatible Design
The low-profile form factor enables integration with many optical platforms. The screw-top chamber simplifies sample exchange and experimental setup while maintaining thermal performance and optical accessibility.
Applications
- Semiconductor reliability testing
- Cryogenic electrical analysis
- Variable-temperature conductivity measurements
- Thin-film transport studies
- Quantum material research
- Dielectric spectroscopy
- Optoelectronic characterisation
- In-situ microscopy with electrical biasing
- Temperature-dependent device testing
Additional Information
| No. of Channels | 2/4 |
|---|---|
| Minimum Temperature | -190° |
| Maximum Temperature | 600°C |
| Sample Size | 23mm x 23mm |
| TYPE | ECH600S |
| Cooling/Heating Method | Liquid nitrogen cooling, Resistance heating |
| Temperature Range | ﹣190℃~600℃ |
| Temperature Stability | ±0.1℃ |
| Heating/Cooling Rate | Maximum Heating Rate:150℃/min, Maximum Cooling Rate:40℃/min |
| Sample Holder | Silver;23mm*23mm |
| Optical Path | Reflection / Transmission(φ2mm Optical Access Hole) |
| Top Window Size | φ25mm*1mm |
| Bottom Window Size | φ10mm*1mm(Transmitted Light Option) |
| Window Material |
JGS2 Fused Silica Glass (Transmission Range: 220 nm - 2500 nm), manually removable and replaceable.
|
| Window Defrosting |
Gas Purge Attachment,Air blowing defrosting at low temperatures
|
| Distance from Window Upper Surface to Sample Holder Upper Surface | 7mm |
| Chamber Height | 6mm |
| Probe | Fixed Probe Holders*4 + Gold-plated tungsten steel probes*4 |
| Probe Port | BNC*4 |
| Sample Stage Potential | Grounded / Electrically Floating |
| Chamber | Atmosphere |
| Dimensions | 156.8mm*143mm*27mm |
| Net Weight | 0.5kg |
| Basic Configuration | GoGo TCS, Motorised Probe Station*1, Temperature controller*1, Cooling controller*1 ,Liquid Nitrogen Tank*1, Recirculating Chiller*1, Cables, Tubing and Accessories |
| Optional |
Customised Temperature Control Software |
| Photo | Product | No. of Channels | Minimum Temperature | Maximum Temperature | Sample Size | Price | |
|---|---|---|---|---|---|---|---|
![]() | GoGo EH1000V-EM Externally Adjustable High Temperature Probe Station | 4 | RT | 1000°C | 20mm x 20mm | > | |
![]() | GoGo EPE120 Peltier Electrical Heating and Cooling Stage | 4 | -25˚C | 125˚C | 40mm x 40mm | > | |
![]() | GoGo EH1000/EH1200 Ultra-High-T Electrical Heating Stage | 4 | RT | 1000°C | 30mm x 30mm | > | |
![]() | GoGo Instruments ECH400V-EC Motorised Probe Station | 2 | -190° | 400°C | 23mm x 23mm | > | |
![]() | GoGo Instruments ECH400V-EB Externally Adjustable Probe Station | 4 | -190° | 400°C | 23mm x 23mm | > | |
![]() | GoGo Instruments ECH400V-EM Externally Adjustable Probe Station | 4 | -190° | 400°C | 23mm x 23mm | > | |
![]() | GoGo Instruments ECH600 Electrical Heating and Cooling Stage | 4 | -190° | 600°C | 23mm x 23mm | > |