  1. Measuring Index of Contact and Intraocular Lenses While Submerged in Hydrating Fluid using the Metricon Prism Coupler

    The conventional way to measure index of contact or intraocular lenses is using an Abbe refractometer where the lens is not immersed in liquid. Advantages of using the Metricon Model 2010/M for measuring such lenses include: Maintains full hydration during measurement: A cell is available to allow the lens to be measured while it is completely immersed in hydrating fluid...
  2. Index Vs Temperature Option (dn/dT) for the Metricon Prism Coupler

    Option 2010-TC allows determination of temperature coefficient of refractive index by measuring index for thin films and bulk materials at temperatures as high as 200˚ C. Temperature coefficient data can also be used to calculate thermal expansion coefficients (Kang et al, Appl. Phys Lett. 81, 1438 (2002)). In the prism coupling technique, measurement of index at elevated temperature is complicated...
  3. Measuring Index/Birefringence of Bulk Polymers and Flexible Polymer Films using the Metricon Prism Coupler

    The Model 2010/M measures refractive index in machine (x), transverse (y), and perpendicular (z) directions for thin flexible polymer films and thicker bulk materials, permitting rapid and accurate determination of polymer density and crystallinity in approximately one minute. In-plane refractive index can also be measured along any arbitrary in-plane direction by a simple rotation of the sample about the coupling...
  4. High Accuracy Measurement Of Resist, Polyimide and Polymer Thin Films using the Metricon Prism Coupler

    The Model 2010/M’s ease in measuring thickness and index of relatively thick and optically absorbing films (including free-standing films) makes it an ideal tool for production or R&D measurements of photoresists, polyimides, or other polymers. In particular, the 2010/M’s routine ±.0005 index resolution (higher resolutions are available) makes possible routine monitoring of the overall processing consistency of these films with...
  5. Spectroscopic Measurements of Index Vs Wavelength (Dispersion) using the Metricon Prism Coupler

    Multiple-wavelength operation is available for Metricon’s Model 2010/M to provide rapid and accurate curves of thin film and bulk material dispersion (index vs wavelength) similar to the results from a spectroscopic ellipsometer. If index is measured at three or more wavelengths a complete index vs wavelength (dispersion) curve can be easily generated in just a few seconds using the built...
  6. Characterization of SPR and Waveguide Structures for Sensor Applications using the Metricon Prism Coupler

    The Metricon Model 2010/M is an ideal tool for developing surface plasmon resonance (SPR) and waveguide structures for use as bio- or other sensors. Such sensor devices usually rely on measuring the angular shift of an SPR resonance or waveguide propagation mode caused by the adsorption of thin layers of target materials on the surface of the sensor. A typical...
  7. Bulk Material or Thick Film Index/Birefringence Measurement using the Metricon Prism Coupler

    The Model 2010/M can operate as a fully-automated refractometer, providing high accuracy measurement of refractive index and index anisotropy for solid or liquid bulk materials and thick films in the index range 1.0 -2.6 without use of toxic or corrosive index matching fluids. This bulk material index measurement is not an option, but a standard feature provided with every system...
  8. Waveguide Loss Measurement with the Metricon Prism Coupler

    This option measures loss of optical wave guides by scanning a fibre optic probe and photodetector down the length of a propagating streak to measure the light intensity scattered from the surface of the guide. The assumption is that at every point on the propagating streak the light scattered from the surface and picked up by the fibre is proportional to the...
  9. Optical Waveguide Characterization with the Metricon Prism Coupler

    Metricon’s Model 2010/M system transforms prism coupling from an esoteric research technique into a routine laboratory analysis measurement. With the 2010/M, wave guide characterization data which typically requires a skilled professional an hour or more to collect with home made apparatus can now be obtained in 30 seconds or less in a format providing complete documentation of results and measurement...
  10. High resolution imaging using LASOS LDM-XT laser diode modules

    The LASOS® LDM-XT laser series is the latest generation of laser diode modules that allows high resolution microscopy for both OEM and Laboratory applications.   Figure 5 LDM-XT laser diode module beam coupling options. LDM-XT can be delivered either (i) free-beam or (ii) by single mode fibre with direct modulation at frequencies up to 300 MHz. The LDM-XT are available in...